Emergency and exit lighting testing for Adelaide commercial buildings, schools, medical practices and strata: the 6-monthly 90-minute discharge test and the annual inspection AS 2293 requires, every fitting logged in a register, and failed fittings repaired or replaced on the spot where you want them to be.

SA Electrical Contractor Licence PGE355384 · NECA member · $20 million public liability · Mon to Fri, 6am to 6pm

Free quotes. On site from 6am.

Request a free quote

Free quote · No obligation · Mon to Fri, 6am to 6pm

10 electricians

20 years in business

40+ years experience

Commercial, industrial, residential

Licence PGE355384

NECA member · $20 million PL

5.0 on Google

7 verified reviews

What the test involves

The 6-monthly test isolates the normal supply and runs every emergency and exit fitting on battery for 90 minutes. A fitting that goes dark early has a failed battery, and a battery is the one thing you can't see from the ground. The annual inspection adds a physical check of each fitting, the wiring, the signage and the escape route it's lighting. Both are recorded per fitting, and the register stays on site.

Who it applies to

  • Commercial buildings and tenancies, with the obligation usually sitting with the owner and passed down through the lease.
  • Schools, where the emergency lighting register is 1 of the first things asked for after an incident.
  • Medical practices and aged care, where evacuation lighting is part of the accreditation picture.
  • Warehouses and factories, particularly where high-bay fittings mean testing at height. See manufacturing and warehousing.
  • Strata and apartment common areas: stairwells, car parks and corridors.

Repairs and upgrades

Failed fittings are replaced with new LED emergency fittings on the same visit where practical, so the register closes clean. If a building has an ageing mix of fittings, we'll price a full replacement to bring the whole site onto 1 type with 1 battery spec, which makes every future test faster. Installation of new emergency lighting is part of our commercial lighting work.

FAQs

Emergency lighting testing questions

How often must emergency lighting be tested?

Every 6 months for the discharge test and every 12 months for the full inspection, under AS 2293. Both results go in a register kept on site.

Our register has lapsed. Can you restart it?

Yes. We survey every fitting, test it, log it, and hand you a register that starts from that date. It's the most common starting point for a new compliance customer.

Can you test emergency lighting outside business hours?

Yes, by arrangement. The discharge test dims the emergency fittings for 90 minutes, which some venues prefer to have happen before opening. Our 6am start covers most of it.